– 6 Mount the nozzle on the spraylance (marking on the adjustmentring at the top) and hand-tighten it(EASY!Lock). Join the spray lance with the triggergun and tighten until hand-tight(EASY!Lock). Release the unlocking device of thepush handle. Pull the push handle out to its endposition. Join the high-pressure hose withtrigger gun and high-pressure con-nection of the appliance and tightenuntil hand-tight (EASY!Lock). WARNINGRisk of injury! Appliance, accessories,supply lines and connections must bein fault-free condition. If they are not ina perfect state then the appliance mustnot be used. DANGER– Danger of injury by electric shock.– The appliance should always beconnected to the electrical mainsusing a plug. It is forbidden to per-manently connect the appliance tothe power supply. The plug is onlyfor mains separation.– The plug and coupling of the exten-sion cable used must be watertight.– Use the extension cord that has anadequate cross-section (see "Tech-nical Data") and unwind it fully fromthe cable drum.For connection values, see type plate/technical data. Unwind the mains cable and place iton the floor. Insert the mains plug into a socket.Observe regulations of water supplier.For connection values refer to techni-cal specifications. Connect the supply hose (min.length 7.5 m, minimum diameter 1/2“) to the water connection point ofthe machine and at the water sup-ply point (for e.g. a tap).NoteThe supply hose is not included. Open the water supply. Screw the suction hose with filter(optional accessory) to the waterconnection. Appliance ventilation:Unscrew the nozzle from the spraylance.Switch on the appliance and let itrun until the water exiting is bubble-free.Let the appliance run for 10 sec-onds – then switch off the applianceswitch. Repeat the procedure sev-eral times. Switch off the appliance and fit thenozzle again.Start upElectrical connection2.1.Water connectionConnection to the water supplyDrawing in water from open reser-voirs9EN