English 5.906-487.0 Rev. 00 (04/10) 47* 1 K(elvin) = 1 °C** 1 mmWS = 98 hPa = 98 mbar9 Technical specificationsTechnical specifications Preliminary valuesAppliance number 1.064-001 / 1.064-002Description HDS 5/11 U/UXMains voltage / phase number V / Ph 230 / 1Supply voltage, permissible voltage tolerance % 6Frequency Hz 50Current pickup, full load (after 10 min.) a 9,5Connection output kW 2,2Electric motor speed 1/min 2790High-pressure nozzle (UX) (US-gpm at 40 psi) Size 032 (033)Steam nozzle Size - - -Safety valve opening pressure (test manometer) MPa (bar) 13-14,5 (130-145)Overflow valve opening pressure (test manometer) MPa (bar) - - -Work pressure full load, standard gun, new nozzle (test manometer) MPa (bar) 9-11 (90-110)Working pressure partial load (test manometer) MPa (bar) - - -Pressure switch (ON) MPa (bar) < 1,5 (< 15)Pressure switch (OFF) MPa (bar) 13 (130)Flow rate, full load I/min 410 - 460Flow rate, partial load (is generated) I/min - - -Flow rate detergent, full load I/min 0 - 0,6Burner, water temperature increase, full load K * 45 - 52Burner nozzle gph 0,55Burner exhaust gas temperature °C < 200Burner exhaust value CO2 % 10 - 11,5Burner soot number Value 0 - 1Fuel pump, adjustment pressure MPa (bar) 1-1,2 (10-12)Air pressure on the burner cover mmWS ** =/< 22Heating oil consumption kg/h 2,7Heating output kW 26High-pressure pump oil volume l 0,1High-pressure pump oil type SAE 15W40Feed pressure water MPa (bar) Max. 0.6 (max. 6)Feed volume water I/min min. 500Feed temperature water °C max. 30Sound dB(A) 76Date: March 2010