– 5– For connection values, see technicaldata and type plate.– The electrical connections must bedone by an electrician according to IEC60364-1. DANGERRisk of injury on account of electric shock!– Unsuitable electrical extension cablescan be hazardous. Only use electricalextension cables outdoors which havebeen approved and labelled for this pur-pose and have an adequate cablecross-section.– Always unwind extension lines completely.– The plug and coupling of the extensioncable used must be watertight.ATTENTIONThe highest allowed net impedance at theelectrical connection point (refer to techni-cal data) is not to be exceeded. In case ofconfusion regarding the power impedancepresent on your connection, please contactyour utilities provider. DANGERDanger of explosion! Do not spray flamma-ble liquids. DANGERRisk of injury! Never use the appliancewithout the spray lance attached. Checkand ensure proper fitting of the spray lanceprior to each use. The screw connection ofthe spray lance must be finger-tight. DANGERRisk of injury! Hold the hand spray gun andthe spray pipe firmly with both hands. DANGERRisk of injury! The trigger and safety levermay not be locked during the operation. DANGERRisk of injury! Contact Customer Service ifthe safety lever is damaged.ATTENTIONRisk of damage! Never operate device withan empty fuel tank. The fuel pump will oth-erwise be destroyed. To open the trigger gun: Actuate thesafety lever and trigger. To close the hand spray gun: Releasethe safety lever and trigger. DANGERRisk of injury! Switch the appliance off priorto replacing nozzle and activate hand spraygun until device is pressureless. Secure the trigger gun. To do so, pushthe safety catch towards the front. Replacing the nozzle.1 Operating with cold water2 Operating with hot water3 Eco setting (hot water max. 60 °C) Set appliance switch to desired operat-ing mode.Indicator lamp for operational readinesslights up.The device starts briefly and turns off, assoon as the working pressure is reached. Release the trigger gun. To do so, pushthe safety catch towards the back.When activating the hand spray gun the de-vice switches back on.Note: If no water comes out of the highpressure nozzle, vent pump. Refer to "Helpwith malfunctions - appliance is not buildingup pressure".Power connectionOperationOpening/closing the trigger gunReplace the nozzleOperating modes0/OFF = OffTurning on the Appliance1 2321EN