English 15 CAUTIONDisconnect the machine from the powersource before making any repair.TROUBLESHOOTINGSymptom Cause SolutionMotor will not start On/Off switch is in the “OFF”(0) position.Turn switch to the “ON” (I) po-sitionPower cord is not plugged in. Plug in power cord.Electrical outlet does notsupply adequate power.Try a different outlet.Tripped GFCI plug. Press “RESET” button onGFCI plug.Tripped circuit breaker. Switch off pressure washer.The reset comes automaticallyonce the temperature of theunit drops.Unit does notreach highpressure.Diameter of garden hose is toosmall.Replace with a 5/8 inch or larg-er garden hose.Water supply is restricted. Check garden hose for kinks,leaks and blockage.Not enough inlet water supply. Open water source full force.Water inlet filter is clogged. Remove filter and rinse out inwarm water.Spray wand is on low pressureposition.Turn spray wand to high pres-sure position.Output pressurevaries high andlow.Not enough inlet water supply. Turn water on full force. Checkgarden hose for kinks, leaks orblockage.Pump is sucking air. Check that hoses and fittingsare air tight. Turn off machineand purge pump by squeezingtrigger gun until a steady flowof water emerges through thenozzle.Water inlet filter is clogged. Remove filter and rinse out inwarm water.Discharge nozzle isobstructed.Blow out or remove debris witha fine needle.Calcified gun, hose or spraywand.Run distilled vinegar throughdetergent suction tube.