Contents - Table Of Contents
- Table Of Contents
- Quick-Start Instructions
- Safety Warnings
- Introduction
- Electrical Ratings
- KBAC-24D Drive Layout
- KBAC-27D Drive Layout
- KBAC-29, 29 (1P), 45, 48 Drive Layout
- KBAC-217, 217S, 217F, 217SF, 416, 416S, 416F, 416SF Drive Layout
- Mounting
- KBAC-27D, 29, 29 (1P), 45, 48 Mechanical Specifications
- KBAC-217, 217S, 217F, 217SF, 416, 416S, 416F, 416SF Mechanical Specifications
- AC Line Input Fusing
- Motor Connection
- Remote Start/Stop Switch Connections
- Run/Fault Relay Connection
- Setting Selectable Jumpers
- Boost Mode Selection (J6)
- Restarting the Drive After a Fault Has Cleared
- Slip Compensation Trimpot (COMP)
- Diagnostic LEDs
|
KBAC SERIES INSTALLATION AND OPERATION MANUAL 7TABLE 2ELECTRICAL RATINGSModel No.Part No. Ac Line Input Fuse orCircuitBreakerRating(Amps)OutputHorsepowerSelection(Jumper J2)2NetWeightGray White 1Volts AC(50/60 Hz)Phase(Ф)MaximumCurrent(Amps AC)VoltageRange(Volts AC)MaximumContinuousLoad Current(Amps/Phase)MaximumHorsepower(HP (kW)) lbs kgKBAC-24D 9987 9988 115 1 14.4 20 0 – 208/230 3.6 1 (0.75) 1 3/4 1/2 1/4 1/8 5.9 2.7208/230 1 8.1 15KBAC-27D 9520 9521 115 1 22 25 0 – 208/230 5.5 1½ (1.13) ─ 1½ 3 1 3/4 1/2 10.3 4.7208/230 1 16.7 20 0 – 208/230 6.7 2 (1.5) 2A B C D EKBAC-29 9528 9529 208/230 1 16.7 20 0 – 208/230 6.7 2 (1.5) ─ 2 4 1½ 1 3/410.3 4.73 11.7 15 0 – 208/230 9.0 3 (2.25) 34KBAC-29 (1P) 10001 10002 208/230 1 20.5 25 0 – 208/230 9.05 3 (2.25) 3 2 1½ 1 3/4KBAC-45 9530 9531 400/460 3 7.2 10 0 – 400/4606 5.5 3 (2.25) 3 2 1½ 1 3/4KBAC-48 9540 9541 400/460 3 11 15 0 – 400/4606 8.3 5 (3.75) 5 3 2 1½ 1A B C ─ ─KBAC-217 8868 8879208/230 3 22.1 25 0 – 208/230 17 5 5 3 2─ ─ 22 10KBAC-217S 8863 8855KBAC-217F 8861 8853KBAC-217SF 8869 8880KBAC-416 8870 8881400/460 3 20.8 25 0 – 400/4606 16 10 10 7.5 3KBAC-416S 8864 8856KBAC-416F 8874 8883KBAC-416SF 8871 8882Notes: 1. White FDA approved finish. 2. Bold indicates factory setting. KBAC-24D: J2 is labeled "1", "3/4", "1/2", "1/4", "1/8" (factory set to the"1" position). KBAC-27D: J2 is labeled "2", "1½", "1", "3/4", "1/2" (factory set to the "1½" position). KBAC-29, (29 (1P), 45, 48: J2 is labeled"A", "B", "C", "D", "E" (factory set according to the table). KBAC-217, 416 Series: J2 is labeled "A", "B", "C" (factory set to the "A" position).3. KBAC-27D: Rated 1½ HP maximum with 115 Volt AC Line input and 2 HP maximum with 208/230 Volt AC Line input. 4. KBAC-29: Rated2 HP maximum with 1-phase AC Line input and 3 HP maximum with 3-phase AC Line input. 5. KBAC-29 (1P): Rated 9 Amps at 35 °C / 95 °Fand derated to 8.3 Amps at 40 °C / 104 °F. For ambient temperatures above 40 °C / 104 °F, the drive is derated 2.5% per °C.6. KBAC-45, 48, 416 Series: Rated 0 – 400 Volts AC for 50 Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.TABLE 3GENERAL PERFORMANCE SPECIFICATIONSDescription Specification Factory Setting115 Volt AC Line Input Voltage Operating Range (Volts AC) 115 (±15%) —208/230 Volt AC Line Input Voltage Operating Range (Volts AC) 208 (-15%) / 230 (+15%) —400/460 Volt AC Line Input Voltage Operating Range (Volts AC) 380 (-15%) – 460 (+15%) —Maximum Load (% Current Overload for 2 Minutes) 150 —Switching Frequency (kHz) (Jumper J12) (3G Drives Only)1 8, 12 8Signal Following Input Voltage Range2 (Volts DC) 0 – 5 —Output Frequency Resolution (Bits, Hz) 10, 0.06 —Maximum Speed Trimpot (MAX) Range (% Frequency Setting) 70 – 110 100Minimum Speed Trimpot (MIN) Range (% Frequency Setting) 0 – 40 0Acceleration Trimpot (ACCEL) Range (Seconds) 0.3 – 20 1.5Deceleration Trimpot (DECEL) Range (Seconds) 0.3 – 20 1.5DC Injection Brake (DECEL) (Seconds) 0.3 – 6.0 1.7Boost Trimpot (BOOST) Range (Volts) 0 – 30 5Current Limit Trimpot (CL) Range (% Full Load) 40 – 200 160Jog Trimpot (JOG) Range (% Frequency Setting) 0 – 100 35Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz) 0 – 3 1.5Motor Frequency Setting (Hz) (Jumper J5) 50, 60 60Output Frequency Multiplier (1X, 2X) (Jumper J4)3 1, 2 1Minimum Operating Frequency at Motor (Hz) 1 —Speed Range (Ratio) 60:1 —Speed Regulation (30:1 Speed Range, 0 – Full Load) (% Base Speed)4 2.5 —Overload Protector Trip Time for Stalled Motor (Seconds) 6 —Undervoltage/Overvoltage Trip Points for 115 Volt AC Line Input (± 5%) (Volts AC)5 76 – 141 —Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line Input (± 5%) (Volts AC)5 151 – 282 —Undervoltage/Overvoltage Trip Points for 400/460 Volt AC Line Input (± 5%) (Volts AC)5 302 – 567 —Run/Fault Relay Output Contact Rating (Amps at 30 Volts DC, 125 Volts AC, 250 Volts AC) 1, 0.5, 0.25 —Operating Temperature Range (°C / °F) 0 – 40 / 32 – 104 —Operating Humidity Range (% Relative, Non-Condensing) 0 – 95 —Storage Temperature (°C / °F) -2.5 – +85 / -13 – +185 —Notes: 1. Third Generation (3G) drives are marked "(3G)" on the product label. 2. Requires an isolated signal. If a non-isolated signal is used,or if using 0 to ±2.5 thru 0 to ±25 Volts DC, or 4 – 20 mA DC signal input, install the Signal Isolator. 3. Allows the motor to operate up to twotimes the rated RPM. Constant horsepower will result when operating the drive in the "X2" mode above the motor rated frequency.4. Dependent on motor performance. 5. Do not operate the drive outside the specified AC Line input voltage operating range. 6. See Table 2above.
PreviousNext |