Resolver at channel 1GB-93.1.7 Tested encodersThe following resolvers have been tested by KEB on it application:• Tamagawa TS 2620 N21 E11 (default)• Tamagawa TS 2641 N11 E64• LTN RE-15-1-A14• LTN RE-21-1-A05• Harowe 10BRCX 401 k1CHowever, this does not restrict the use of rotary encoder with same specifications of othermanufacturers.3.2 Channel 2The description of input X3B is depending on the used encoder interface. It is described ina separate manual.4. Start-upAfter the installation or exchange of an encoder interface some adjustments of the inverter/servo software have to be done before operation:• Switch on inverter• Select application mode• Select parameter Ec.00 and control whether value „19: resolver interface“ is entered.The displayed value has to be confirmed by „ENTER“ in any case.• Select Ec.42 and adjust the encoder breakage recognition dependent on the case ofoperation.The resolver evaluation block generates incremental signals, which can beoutput via encoder simulation (channel 2 = TTL output). The number of thegenerated pulses is indicated in Ec.01. Parameter Ec.07 is without function.Exception: control card application