4.1 System variationsThe cabinet system is available in different variations which can be combined. The basesystem always serves as basis.4.1.1 basic system• Circuit breaker with motor drive• Varistors• HF filter• AFE filter• Drive converter• Motor connection terminals• LW heat exchanger• Liquid distributors• Control elements (HMI, DEIF I / O outputs, STO, 24V DC supply, PLC control, bussystem)4.1.2 Basic system with additional sinusoidal output filterThe basic system is extended by an additional 600 mm TS8 control cabinet, whichcontains the sinus output filter. Optionally, braking resistors can be installed above thesine output filter.4.1.3 Accessories and optionsThe cabinet system can be ordered in different variants. There are several options thatextend the scope of functions. These options are factory-integrated when ordering andwill be taken into consideration in the control cabinet documentation, however theymay cause a change of the dimensions.basic system with additional connection cabinetThe basic system is extended by an additional 200 mm TS8 control cabinet, which offersthe possibility to insert and connect the supply lines (L1 / L2 / L3) from above.basic system with main switch and NH fuseThe basic system is extended by an additional 400 mm TS8 control cabinet. Instead ofthe circuit breaker, there is a contactor, e.g. DIL 1000. The additional control cabinet isequipped with a mechanical main switch, NH fuses, as well as the mains connections.basic system with Dc-busbarIt is possible to install a DC-busbar with DC fuses above the cabinet system in order toconnect additional components. This should be designed and configured together withKEB.40OVErVIEW cAbINET SYSTEM