GB - 7Preface1.6 Part code27 . F5 . A B U-9 0 0 ACooling0, 5, A, F Heat sink (standard)1, B, G Flat rear2, C, H Water-cooling system3, D, I ConvectionEncoder interface0: noneSwitching frequency; short time current limit; overcurrent limit0 2 kHz; 125 %; 150 % 5 4 kHz; 150 %; 180 % A 8 kHz; 180 %; 216 % F 16 kHz; 200 %; 240 %1 4 kHz; 125 %; 150 % 6 8 kHz; 150 %; 180 % B 16 kHz; 180 %; 216 % G 2 kHz; 400 %; 480 %2 8 kHz; 125 %; 150 % 7 16 kHz; 150 %; 180 % C 2 kHz; 200 %; 240 % H 4 kHz; 400 %; 480 %3 16 kHz; 125 %; 150 % 8 2 kHz; 180 %; 216 % D 4 kHz; 200 %; 240 % I 8 kHz; 400 %; 480 %4 2 kHz; 150 %; 180 % 9 4 kHz; 180 %; 216 % E 8 kHz; 200 %; 240 % K 16 kHz; 400 %; 480 %Input identification0 1ph 230 V AC/DC 5 400 V class DC A 6ph 400 V AC1 3ph 230 V AC/DC 6 1ph 230 V AC B 3ph 600 V AC2 1/3ph 230 V AC/DC 7 3ph 230 V AC C 6ph 600 V AC3 3ph 400 V AC/DC 8 1/3ph 230 V AC D 600 V DC4 230 V class DC 9 3ph 400 V ACHousing type A, B, D, E, G, H, R, U, W, PInternal options (A...D with STO relay according to EN954-1 / 1997)0, A noneB Braking transistor without resistance monitoring1, 5 Braking transistor with resistor monitoring2, C integrated EMC filter3, D Braking transistor without resistance monitoring and EMC filter7 Braking transistor with resistor monitoring and EMC filterControl typeA APPLICATION K like A with safety technologyC COMPACT (controlled frequency inverter)E SCL P like E with safety technologyG GENERAL (controlled frequency inverter)H ASCL L like H with safety technologyM MULTI (regulated, field-oriented frequency inverter for three-phase asynchronous mo-tors)S SERVO (regulated frequency inverter for synchronous motors)Series F5/F6Inverter size