FORM NO. 56041494 / SelecTrac™ 17T / 17THP - 7CLEANING UPHOLSTERYCleaning upholstery with success requires a good knowledge of the type of fabricto be worked on. Look for the cleaning instruction label sewn on the undersideof the furniture for recommended method of cleaning the fabric. Extraction worksperfectly on most synthetic fabrics including synthetic velvets.NOTE: If the label calls for dry cleaning, do not attempt to clean with the wetextraction method; otherwise, damage to the fabric could occur.Before proceeding, test the fabric for colorfastness. Apply a small amount ofready-to-use cleaning solution on the fabric in an inconspicuous spot. Wait for2-3 minutes and rub the area with a white terry cloth towel. If no color comes offonto the towel, the fabric should be safe to clean. If a little color comes off, thereis some risk of colors running when you clean. It may be possible to stabilizecolors by cleaning with an acidic rinse.NOTE: On KX-17THP model, adjust the pump “operating pressure” to 50 PSI orbelow for upholstery cleaning (see PRESSURE ADJUSTMENT).Prepare the machine, except attach an upholstery tool to the vacuum / solutionhose assembly.Clean with using as little solution as possible. Make overlapping passes toprevent streaking. Go over the area you just cleaned without depressing the lever(vacuum only) and gauge the amount of moisture extracted through the viewwindow for dryness. On heavily soiled areas like arm rests, pre-treat with arecommended pre-spray and/or hold the upholstery tool a few inches above thefabric and press lever to spray on the solution before making a pass.PRESSURE ADJUSTMENT (FIGURE 10)Using the pressure adjustment and gauge on the side of the unit, adjust the pumpsystem to the desired “operating pressure” while the cleaning tool is on (spray-ing).EMPTYING THE RECOVERY BLADDER (FIG. 11)When you run out of solution, turn off the pump. Attach the drain elbow on thedrain valve. Place a pail under the down spout and pull up the drain valve T-handle. Dirty solution will pour out until the bladder is empty. Close the drainvalve. Use a clean bucket when you refill the solution tank.EMPTYING THE SOLUTION TANK (FIGURE 12)For model KX-17T, place a bucket under the drain valve. Remove the recoverybladder fork, slide the bladder off the seal and open the drain valve.For model KX-17THP there are two ways. The first is as mentioned above. Thesecond is by connecting the pump priming hose to the female fitting on the backof the machine. Place the other end in a bucket and turn on the pump until thetank is empty.DRY VACUUMINGCAUTION!Optional dry vacuuming bag must be installed or damage tovacuum motor will occur.Open lid and install optional dry vacuuming bag on dirty solution inlet by slippingneck of bag around inlet, and closing the clamp tight. Attach vacuum hose to inleton lid, and preferred vacuuming tool on other end of hose. Plug the power cordinto a grounded outlet and turn on the vacuum switch.CLEAN UP AND STORAGEStore the machine in a cool dry place. Wind the extension cord in a circle andhang on the cord hook provided on the machine. Be sure not to wind the cordtighter than necessary.Avoid prolonged exposure of machine to freezing temperatures during storageor transporting.MAINTENANCEWARNING!AVOID POSSIBLE INJURY OR ELECTRIC SHOCK, DISCON-NECT THE POWER CORD FROM THE ELECTRICAL OUTLET.• Remove dirt and lint from the solution tank filter, vacuum lint filter, recoverynozzle, and spray nozzle.• Reduce the build up of chemical residue by running 8 ounces of vinegarfor every gallon of water through the machine once a week. Be sure thevinegar solution sprays into an appropriate bucket or drain. When finished,run hot clean water through the machine.CAUTION!Do not use vinegar solution on carpet.• Spray quick connect coupler with WD-40 or equivalent lubricant to preventsticking.• Apply light oil on gate seals of drain valve.https://harrissupplyind.com - To Order Parts Call 608-268-8080