User manual Kabola B-serie, 1-4-2005 11Figure 11Figure 124.1.7 Connecting the oil filter and oil burnerTo connect the filter to the boiler follow the procedure below (see also figure 11)1. Remove the burner cover (1);2. Connect the oil pump (2) to the oil-filter (3), usingthe included fuel hoses. Make sure thatthe flow directions on the pump comply withthose on the filter.3. Connect the fuel line from the tank to the filter(5A). The fuel line must have a outer diameter of8mm and must be made from copper or steel.The fuel has to be connected directly to the oiltank. Correct functioning of the burner can notbe guaranteed when a fuel manifold or T-connection is installed.4. Connect the plug (4) from the boiler to theburner.Hint: When the oil tank is situated below the boiler orwhen the oil supply line comes from below the boiler, it isadvisable to use a self bleeding oil filter. This preventsunnecessary malfunctioning of the burner(see figure 12).