Any previous data sheet issues have now become invalid.KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820www.kathrein.comPage 2 of 2936.4037/a Subject to alteration.Installation of the feederline connector and RCU (optional):In order to protect the adjustment mechanism, the protective caps have to be attached duringfeederline installation!Carefully place the connector andfi x the nut using a torque-wrench(according to the manufacturersguidelines).After feederline installation, theoptional remote control units(RCUs) can be mounted.These tools are suitable for 7-16 connectors with a wrench size of27 or 32 mm | 1.1 or 1.3 inches, and the RCU attachment nut with awrench size of 41 mm | 1.6 inches.Tighten nuts within a torque range of 25 – 33 Nm depending onconnector manufacturers’ specifications, respectively the RCU nutwith a torque range of 15 – 18 Nm.Kathrein installation set: Type No. 85010077Set has to be ordered separately!Set consists of three spanners of divers width27, 32 and 41 mm | 1.1, 1.3 and 1.6 inches32 | 1.341 | 1.627 | 1.11/2˝ square actuationaccording toDIN 3120 Form CAll dimensions in mm | inchesColour coding:Correlation of each RF input to:– the corresponding adjustment mechanism– the frequency range– the polarizationVentilation holeSpindle with tilting scale7-16 female (long neck)Adjustment mechanism(protective cap removed)General Instructionsfor Feederline and RCU Installationfor AntennasPlease note: In order not to damage the interfaces, please make sure that only the right tools are used.Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrenchwidth.Description of bottom end cap (exemplary picture):