6 – Fastcool 10 / 0648 © kemppi oy4.1. dAILy MAINTENANCEThe following maintenance opeations should be carried out daily:• Check water level and input flow, add liquid if needed.• Check cables and connections. Tighten, if necessary and replace defect parts4.2. EvERy SIXTh MONThSThe following maintenance opeations should be carried out at least every sixth months:• Clean off dust and dirt. Change the cooling liquid and wash up the pipes and water reservoirwith pure water.• Check seals, cables and connections. Tighten, if necessary and replace defect parts.4.3. TROUbLE ShOOTINGSee also 3.2. Overheat signal lamp.Overheat signal lamp is lit.The unit is overheated.• Check water circulation.• Check that there is enough free space behind the machine for cooling air circulation.Error code Err 5 on the FastMig panel• Check the liquid hoses for damages.• Remove any hose blockages.• Check water circulation, add liquid if needed.For further information and assistance, contact your nearest Kemppi service workshop.5. dISPOSAL OF ThE MAChINEDo not dispose of electrical equipment together with normal waste!In observance of European Directive 2002/96/EC on Waste Electrical and ElectronicEquipment and its implementation in accordance with national law, electrical equipmentthat has reached the end of its life must be collected separately and returned to anenvironmentally compatible recycling facility. As the owner of the equipment, you shouldget information on approved collection systems from our local representative.By applying this European Directive you will improve the environment and humanhealth!