ENSF 52W/SF 53W and MS 200/MS 300> 5 sSETUP A + D B WIRE INCHGAS TESTchch clearMINILOGSETONMEMORYPANELSAVESETquicksetupwelddataARC FORCEDYNAMICS4T2TSETUPPOWERUSELECTSYNERGICPROGRAMMMAWISE1-MIGMIGA Vm/minmmSF 52W W004269MMA PENremoteCHC WIRE INCHGAS TESTchch clearMINILOGSETONMEMORYPANELSAVESETquicksetupwelddataARC FORCEDYNAMICS4T2TSETUPPOWERUSELECTSYNERGICPROGRAMMMAWISE1-MIGMIGA Vm/minmmW004269MMA PENremoteCHSF 52WFastMig PulseThe factory default setting for FastMig Pulse is AUTO. If a cooling unit is not connected andthe operator tries to establish air cooled operation together with an air cooled gun, Err 27is displayed. To establish air cooled operation, select cooler ‘OFF’. This is done in the ‘SystemConfig Menu’ as follows: Press the Menu button on the P65 power source panel. Move themenu display arrow (via panels left-hand up-down arrow keys) to select ‘System Config Menu’and then press select button. Choose ‘Water Cooling:Auto’ and change via control knob tosetting ‘Water Cooling:OFF’, then press Back/Exit. Cooler will then be set to the ‘OFF’ state forair cooled operation. Reset power source via on/off switch and continue welding.When selected, the operation of the cooling unit is automatic, starting when weldingcommences. When welding stops the pump will continue operation for approx. 5 min,so reducing the gun and the cooling liquid to ambient temperature. Read the operationinstructions for the FastCool 10 unit.2.17 MXF hanging kitThe MXF 63, 65 and 67 wire feed units can be hanged from a special hanging kit available asan accessory. This allows the wire feed unit to be suspended above the work area.3. CONTROL PANEL OPERATIONSMXF wire feeders can be connected to either FastMig Pulse, FastMig KMS or FastMig M powersources.PF 63 and PF 65 control panel are compatible with FastMig Pulse.SF 53W and SF 54 or SF 51 and SF 52W panels enable compatibility with FastMig KMS powersources.MR 200, MR 300, MS 200 and MS 300 panels are compatible with FastMig M power sources.FastMig MXF 63, 65, 6714