EN3.2.3 Activation and setup parameter adjustment1. Press remote selection button (11) for at least 3 seconds, until the text ”Set” appears onthe screen.2. Choose the needed parameter with the welding current adjustment knob (6).3. To select the required parameter, press the remote selection button (11). You can movefrom adjustment mode to selection mode with a new press of the button (11).4. Use the Welding current adjustment knob (6) to adjust the parameter value.5. You can exit Setup mode with a long press of remote selection button (11). Setupparameters are saved when you exit Setup.Setup menu structureAdvanced control panelName Function Description FactorydefaultAdjustment rangeAnt. Antifreeze If Antifreeze selection is On, themachine cuts off the power and protectsthe electrode if sticking occurs duringthe weldingOn On/OFFCab. Long cables Long cable mode for welding circuits of50 m and longer (max. 80 m)OFF On/OFFGen. Generator Generator mode for generator use andfluctuating mains networksOFF On/OFFCU CV mode CV mode selection OFF On/OFFrc Remote selection Remote operation mode. Selectionbetween analog and wireless remotecontrollers (R10/R11T)r10 r10/r11rcL Remote low currentlimitLimits the remote adjustment range.Allows more exact remote adjustment.30 30–MAXrcH Remote high currentlimitLimits the remote adjustment range.Allows more exact remote adjustment.MAX 30–MAXUrd VRD selection Reduces open circuit voltage below 35V OFF(device specific)On/OFFFac. Restore factorysettingsRestores setup and panel settings tofactory defaultOFF rES/OFFConstant Voltage (CV)In CV mode the welding machine maintains a relatively stable, consistent voltage regardlessof the amperage. This mode is recommended to be used with carbon arc gouging and in MIG/MAG welding with Kemppi voltage sensing wire feed systems. CV mode is activated throughthe setup menu.Voltage Reduction Device (VRD)Master S 400 and 500 contain a voltage reduction device (VRD), which reduces the open-circuit voltage below 35 V. This reduces the risk of electric shock in particularly dangerousenvironments, such as closed or damp spaces. VRD is activated through the setup menu.Master S 400, 5008