MasterTig 235ACDC, 325DC, 335ACDCOperating manual - EN3.3.7 Settings viewTo adjust settings:1. Go to the Settings view.2. Turn the control knob (1) to browse through the settings groups and parameters.3. Select a parameter to be adjusted or changed by pressing the control knob button (1).4. Adjust or change the setting by turning the control knob (1).5. Close the parameter setting by pressing the control knob button (1).Some of the settings are e.g. current mode and welding process specific and are visible or not visible in the settingsmenu accordingly.Common welding settings:Welding process: TIG / MMA (Default = TIG)>> Selecting a welding process changes automatically to the last active channel for the selected process.>> For safety reason, the device always starts up in TIG.Current limit min: TIG: 2 A / MMA: 8 A, step 1 A *Current limit max: TIG: power source's nominal value / MMA: power source's max. MMA current, step 1 A *Remote control mode: OFF / Remote / Torch (Default = OFF)>> When a remote control or a torch remote control is selected, the welding current adjustment on the controlpanel is disabled.Remote control min: Min = “Current limit min”, Max = “Current limit max”Remote control max: Min = “Current limit min”, Max = “Current limit max”Button remote channel control: OFF / ON (Default = OFF)Wireless remote: Pairing starts automatically when selected>> New pairing information replaces the old information.© Kemppi 46/77 1920900 / 1939