Function panels1 TIG HF ignition/ contact ignition selection2 AC-TIG frequency adjustment 50…200 Hz3 Postgas time adjustment 0…100 s.4 Welding current downslope time adjustment 0…15 s.5 Current adjustment knob/selected parameter adj6 Local-/remote control selection/code lock11 Minilog-function selection/adjustment -80…+20 %12 Pre gas time adjustment/code lock13 Welding current upslope time adjustment 0…5 s.14 2T/4T-selection19 Broken arc welding20 MMA welding dynamics adjustment21 MMA welding selection22 AC-TIG balance adjustment -70…+70 %1 TIG HF ignition/ contact ignition selection2 AC-TIG frequency adjustment 50…200 Hz3 Postgas time adjustment 0…100 s4 Welding current downslope time adjustment 0…15 s.5 Current adjustment knob/selected parameter adj6 Local-/remote control selection/code lock7 Pulse-TIG pulse height adjustment 3…200, 250,350 A/pulse ratio adjustment 10…75 %8 Pulse-TIG selection9 Pulse-TIG background current adjustment 20…40 %/frequency adjustment 0,1…300 Hz10 Start current adjustment-70...+70 %11 Minilog-function selection/adjustment -80…+20 %12 Pregas time adjustment/code lock13 Welding current upslope time adjustment 0…5 s.14 Fusion spot welding selection/adjustment 0…10 s.15 2T/4T-selection16 Memory channels selection17 Welding values saving into the memory channels18 Memory channel selection19 Broken arc welding20 MMA welding dynamics adjustment21 MMA welding selection22 AC-TIG balance adjustment -70…+70 %Minilog-panelPulsepanel9