WARNINGElectricalShock Or Personal InjuryHazardDisconnect electrical supply beforeservicing or cleaning the unit. Failureto do so could result in electricalshockor personal injuryfrom cleaner sud-denly starting.Frequently check and remove hair, stringand lint build-up in the brush area. If build-up becomes excessive, follow the stepsbelow. Should the belt become loose orshould it break, follow the Belt RemovalInstructions.TO REMOVE NOZZLE COVERDisconnect electrical supply.To protect the floor surface, always placepaper under the nozzle any time the nozzlecover is removed.Release the nozzle c_)ver by rotating thenozzle cover retainerg to the UNLOCKposition. Grasp back of nozzle on each sideand lift up to remove it from nozzle cover.NozzleCoverCarefully remove any residue that may existin the belt area.Personal InjuryHazardAlways unplugthe vacuum cleanerbefore cleaning the brush area as agi-tator may suddenly restart. Failure todo so can result in personal injury.TO REMOVE BELT/CLEANAGITATORAgitatorPosition hands on the agitator. If the belt isstill attached to the agitator, there will betension on it.Carefully lift the right end of the agitator andthen lift the left end.Remove the worn or broken belt from themotor drive shaft.Personal Injury HazardBe careful when removingthe agitatoras the belt tension is high. Failure todo so could result in personal injuryfrom the agitator releasing quicklyandsnappingaway.16