Kenwood DTF-200 Service Manual
AE AG AI AK AMAF AH AJ AL ANY07-2882-70DTF-200IC15ABCEDDTF-200(1/2)Q72Q71Q52Q53Q65Q66Q68Q67Q70Q69CN5CN3D19Q5IC10 (3/5)D22D23D21D20D46D45D44D43IC10 (4/5)Q6D24BANKING CARDCA CARDJ1D26D27D28D29D30D31D32D33D34D35D36D37D38D39D40D41D42J2CN8Q74Q73D25B LINEB LINEGND LINESIGNAL LINEIC1 : KM416S1120DTG8 orIC2 : SN74LVU04APWIC3 : 24LC32AT/SN orIC4 : STI5510AIC5 : AS4LC1M16E5-60IC9 :29LV400B90PFTNIC10 : SN74LVC32APWIC11,18 : NJM4580VIC12 : RC2324DPLIC13 : SN74LV245APWIC15 : HIN232CB-T orIC16 : TC9271FSIC17 : STV6411ADIC19 : AK4351IC21 : D780021AYGKN05IC22 : PST9130NRIC23 : PST9142NRQ1,11,14-16,19,25,26,31,39-42,48,51,53-55,57-64,75-77 : 2SC4081(R,S)Q2,3,43,56 : DTA124EUAQ5,6,8,9,12,13,17,18,20-24,27,28,32,37,38,50 : 2SA1576A(R,S)Q7 : 2SA1862Q29,30,66,67,69,71,74 : 2SB1561Q33-35,44-47,49,65,68,70,72,73 : DTC123EUAQ36 : 2SA1906(E,F)D1 : KV1471D2,3,5-7,12,15,17,18,25,47,50,51,53-58,60-65,67,70 : 1SS355D4,11 : PTZ15AD8,9,13,14,48 : 1SR154-400D10 : SM6T150AD16,52,69 : RB161L-40D19-24,26-46,49,59,66 : UDZ5.1BPH1,2 : AQY210EHXPH4,5 : LTV-814SINTERFACEPARALLELBC2/2CON32/2WH1X14-A/32/2CN1X14-B/32/2X14-C/3WH22/2WH3X14-C/3A1 : W02-2723-05MB81F161622BIC7,8 AT49LV819290TC or:AM29LV800BB90EM29W800AB90N1 orM29W400BB90N1 orMAX232DWAT24C32N10SC25 orM24C32-WMN1TQ52 2SD2391:DTF-200 (X05-511X-XX)R385 10KR384 2.2KR388 2.2KR390 2.2K+C23610u501KR4115.6KR4090.1C137+C24110u502.7KR4081uHL260.1C213R360 1.5KR295 10KC66+10u50L41uH0.1C212C2170.110u50C77R367 10KR364 330+R382 680R383 10KC78+10u50L51uHC2180.112345678910+32V+21/17V+17V/21V+12VMUTE+5V+3.3VAGNDGND-5VC19 0.1C300 0.1C302 0.1C301 0.1C305 0.1C304 0.1C303 0.15VA+5VDS+3.3VA+5VDU+3.3VD+21/17V+32V+5VA+12VU+12VS+8.5VU+21/17V+12VU+12VS+8.5VU+5VDS+5VA+32V5VA+5VDU+3.3VA+3.3VD1234567891011DATAVCCRSTCLKDETECTGNDDATAVCCRSTCLKDETECTR184 220R186 1.8R187 220R188 220R189 470R190 220R192 1.8R194 220R195 220R196 4700.1C524.7KR1784.7KR1812200PC5133KR17747KR17910KR180R18312K9 81024120022120120221823921912 111312K2371984.7KR20247KR199R20010K2200PC53R19733KR1984.7KR2010.1C5412345678910111213141516171819202122232425STROBED0D1D2D3D4D5D6D7ACKBUSYPERRORSELECTAUTOFDFAULTINITSELECTINL7L8L9L10L11C246 100PC247 100PC248 100PC249 100PC250 100PC251 100PC252 100PC253 100PC254 100PC255 100PC256 100PC257 100PC258 100PC259 100PC260 100PC261 100PC262 100P1.2KCP75 41858411.2KCP58514CP61.2KCP3 47989910010561848382CP4 4714851 8544 581CP2 47919089811066263 R182 474142910111213141516R2OUTT2INT1INR1OUTR1INT1OUTGNDVCC87654321R2INT2OUTVS-C2-C2+C1-VS+C1+123456789DCDRXDTXDDTRDSRRTSCTSRIL12680R204680R205C266 100PC265 100PC263 100PC264 100P1u50+C55+1u50C56+C591u502124140.1+C5847u25C571u50C60+47uHL241716151413121110987654321L14L15L13L64100PC282100PC283C284100PC285100PC286100PC287100PC288100PC289100PC290100PC291100PC292100PC293100PC294100P5758596067451231161848+C6810u500.1C674.7KR4450.1C30846+8.5VU+12VS+12VU+32V+5VA+21/17V+5VDU+3.3VA5VA+5VDS+3.3VD+21/17V+32V+12VU+12V+3.3VD+5VA+5VDU5VA+5VDS+3.3VA+8.5VU+3.3VA+5VDS+3.3VD+3.3VA+5VA+5VDU5VA+5VDS+5VDS+5V+5V+3.3V+3.3V+3.3V+5VDU+5VDS+5VDU+5VDSVCC+5VDU+5VDS+5VDUVCC+5VDSB+BBA+5VDU+12VU+12VU+12VU+12VUAA04.7KNONONOYESNONOYESX05-5112-74FISNFRANCEX05-5112-75X05-5112-76X05-5112-77HOLLANDITALYSPAIN NOYESNOYESYESNONOYESNOYESNOYES0NOUNIT No.DESTINATIONCOUNTRY ABB. CBA C30 149,150,314R144,146,147,PH1,280L77,D6 R11,12,166Q3,54 R155R154 401R399,YESC40YES NO0.1C29932.7V12.1V22.0V-5.0V12.1V8.4V5.0V4.9V3.2V0V4.9V4.9V4.9V0V4.9V4.4V4.9V12.1V4.4V5.0V5.0V4.9V4.8V11.4V5.6V3.3V2.6V2.6V9.1V3.2VCAUTION: For continued safety, replace safety critical com-ponents only with manufacturer's recommended parts (referto parts list). indicates safety critical components. Forcontinued protection against risk of fire, replace only withsame type and rating fuse(s). To reduce the risk of electricshock, leakage-current or resistance measurements shall becarried out (exposed parts are acceptably insulated from thesupply circuit) before the appliance is returned to the cus-tomer.The DC voltage is an actual reading measured with a highimpedance type voltmeter with no signal input. The mea-surement value may vary depending on the measuringinstruments used or on the product. |
Related manuals for Kenwood DTF-200
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine