KDC-3025/325/5026/G911. Special display when the display is All ONPressing the Preset keys while the power is All OFF dis-plays the following information.[14seg 8 digits]1key Version display (8 digits, Month/Day/Hour/Minute)(Display) xxxxxxxx2key3key Short press: View power ON time. (The All OFFperiod is not counted.)Long press/hold: Clear power ON time.(Display) PONxxxxx Max. 65535 (hours)4key Short press: Display TAPE operation time.Long press/hold: Clear TAPE operation time.(Display) TPTxxxxx Max. 65535 (hours)5key Short press: Display TAPE ejection count.Long press/hold: Clear TAPE ejection count.(Display) EJCxxxxx Max. 65535 (times)6key Short press: Display Panel open/close count.Long press/hold: Clear Panel open/close count.(Display) PCxxxxx Max. 655359 (times)FM key Display ROM colection version(Display) ROM Rxxx Invalid :ROM R–[15x7dot 12 digits]1key Version display (8 digits, Month/Day/Hour/Minute)(Display) SYS_xxxxxxxx2key3key Short press: View power ON time. (The All OFFperiod is not counted.)Long press/hold: Clear power ON time.(Display) PonTim_xxxxx Max. 65535 (hours)4key Short press: Display TAPE operation time.Long press/hold: Clear TAPE operation time.(Display) TPTim_xxxxx Max. 65535 (hours)5key Short press: Display TAPE ejection count.Long press/hold: Clear TAPE ejection count.(Display) EjeCnt_xxxxx Max. 65535(times)6key Short press: Display Panel open/close count.Long press/hold: Clear Panel open/close count.(Display) PnCnt_xxxxxx Max. 655359 (times)FM key Display ROM colection version(Display) ROM Rxxx Invalid: ROM R–12. Other specifications• The line mute against times are 1 second from 10 sec-onds when starting the test mode.■ Security• Forced Power ON mode (All models)Even when the security is approved, resetting the unit whileholding the Q and 4 keys makes it possible to turn thepower ON for 30 minutes.After 30 minutes have elapsed, itis not possible to return to the previous condition unlessthe unit is reset again.• Method of registration of the security code afterEEPROM (F/E) replacement (Code security model)1. Enter the test mode. (See How to enter the test mode)2. Press the MENU key to enter the MENU.3. When the message “Security” is displayed, press andhold the Track Up/Down key for 1second to enter theSecurity registration mode.4. Enter the code using the FM/AM/Track Down keys.• FM key : Number up• AM key : Number down• Track Up key : Cursor right shift• Track Down key : Cursor left shift5. Hold down the Track Up key for at least 3 seconds andthe message, “RE-ENTER” appears, so once again en-ter the code according to Step 4 above.6. Press and hold the Track Up key for 3 seconds until “AP-PROVED” is displayed.7. Exit from the test mode. (See 2 How to exit from the testmode)(Note) All Clear is not applicable to the security code ofthis model.• Simplified method of clearing the security code1. While the code entry is requested, press and hold theTrack Up key for 3 seconds while holding the AUTO keypressed. (----will dissappear.)2. Enter “KCAR” from the remote.• Press the 5 key on the remote twice, then press theTrack Up key. (This enters “K”)• Press the 2 key on the remote 3 times, then press theTrack Up key. (This enters “C”)• Press the 2 key on the remote once, then press theTrack Up key. (This enters “A”)• Press the 7 key on the remote twice, then press theTrack Up key. (This enters “R”)3. Security function is canceled and the unit enters the AllOFF mode.4. If you commit a mistake in the code entry, the unit en-ters the code request mode.TEST MODEwww . xiaoyu163. comQQ 376315150 992894298TEL 13942296513 992894298051513673QQTEL 13942296513 QQ 376315150 892498299TEL 13942296513 QQ 376315150 892498299