3COMPONENTS DESCRIPTION SWITCH UNIT (X16-2052-71/2362-70)Ref. No. Function OperationIC1 LCD DriverIC2 Remote-control ICQ1 Key-scan Start SW "ON" when the base goes "L".Q2 Key-illuminations SW (GREEN) ON (Key-illuminations Green) when the base goes "H".Q3 Key-illuminations SW (RED) ON (Key-illuminations RED) when the base goes "H". ELECTRIC UNIT (X25-9622-71/9812-70)Ref. No. Function OperationIC1 System MI-COMIC2 E-VOL. & N.C. MPXIC3 Power Supply ICIC4 Power ICIC6 Analog SW (Mute logic)IC7 RDS DemodulatorIC8 Reset IC “L” : detection voltage below 3.6VIC9 CD mechanism 5V AVRQ1 SERGE Det. ON when the base goes “Hi”.Q2 B.U. Det. ON when the base goes “Hi” during BU applied.Q3 ACC Det. ON when the base goes “Hi” during ACC applied.Q4 SW 5V ON when the base goes “Lo”.Q21 SERVO +B AVR Output voltage 7.4VQ22 SW 14V ON when the base goes “Hi”.Q41 MECHA 5V AVR SW ON when the base goes “Lo”.Q101 Buffer The buffer for composite signals.Q151 Panel 5V SW ON when the base goes “Lo”.Q201 Noise bufferQ350 Mute driver for Audio mute SW ON when the base goes “Lo”.Q351 Pre mute SWAudio Pre-output is muted when the base goes “Hi”.Q352 Pre mute SWQ401 DSI ILLUMI SW ON when the base goes “Lo”.KDC-M4524/G/Y/GY