TK-216040LEVEL DIAGRAMC365 C475Q404–119.5dBm–117.0dBm –115.0dBm –106.0Bm –118.0dBmIC601500mW16mVrmsVCOC4416mVrms 320mVrms12.6dBmC441 C417XF401RF (CENTER FREQUENCY) IF1 (49.95MHz)IF2(450kHz) AF(1kHz)IC605C645C648C85C81AF (1kHz)RF (CENTER FREQUENCY)RXLOD401D2012dBmC24631.8dBmC3444.8WRF (CENTER FREQUENCY)AF (1kHz)RXTX2.7dBmC203PLLFM IFSYSTEM–104.0dBm 217mVrms358mVrmsC414 IC602IC401AQUAIC601AQUAQ206 Q207 Q211To make measurements in the AF section, connectthe AC level meter. (ANT input : -53dBm, 1kHz FM,3kHz DEV(WIDE).)In the RF section, use a 1000pF coupling capacitor.(The display shows the SSG input value required toobtain 12dB SINAD Without Local Level.)AG is set to the MIC input becomes 3kHz DEV. at1kHz MOD. (WIDE)To make measurements in the AF section, connectthe AC level meter.In the RF section, use a 1000pF coupling capacitor.