NX-22046X57-804 R40-10 (None)0-11 0ΩNote:• The 0Ω resistor (R4) is used to differentiate the destina-tion with a visual check. These are not connected withany PCB pattern; they are specifically for production con-trol. There is no need to change the mount of the resistor.• There is no difference between the schematic diagram ofthe Service TX-RX unit (X57-8040-11) and the schematicdiagram of the original TX-RX unit (X57-8040-10). (R4 isconnected with GND (ground) only.)■ Supplied Accessories of “Service TX-RX unit”Item (Including Parts Number) QuantityTX-RX Unit (X57-804) 1Kenwood ESN Label 1NXDN ESN Label 1MPT ESN Label 1Addendum (B59-2655-XX) 1■ “Service TX-RX unit” DataThe following data is written on the service TX-RX unit:Data Type DescriptionFirmware NX-220 K type Firmware.FPU Data(PC programming mode) X57-804 (NX-220) Kx type data.Various Adjustment Data(PC Test mode)General adjustment values for theX57-804 (NX-220).Kenwood ESNModel name: NX-220SType: KxThe same number as the KenwoodESN label is written.NXDN ESN/MPT ESN The same number as the NXDN ESN/MPT ESN label is written.■ After Changing the PCB1. After changing the printed circuit board, write the up-to-date Firmware following the instructions in the “RE-ALIGNMENT - 6.Firmware Programming Mode”.• Write the Firmware in accordance to the Market. If youwrite different Market Firmware, there are times com-munication with the FPU is not possible.2. Using the KPG-141D(C), select your desired item (ModelName and Frequency) from the Model> Product Informa-tion menu, then use Program> Write Data to the Trans-ceiver to write the FPU data (PC Programming mode).When writing to the transceiver, a Warning Message,corresponding to the item selected, appears. Click [OK] tocontinue writing the data.3. Enter Program> Test Mode, then adjust the various ad-justment data (PC Test Mode) as described in the “AD-JUSTMENT”.TROUBLE SHOOTING4. Attach the new labels corresponding to the new printedcircuit board. (Refer to the images below for label place-ment.)5. If necessary, write the FPU data used by the customerwith the KPG-141D(C).Note:• When using the ESN Validation function of Trunking, theESN number changes when the circuit board is changed(the number is written on the circuit board); the TrunkingSystem cannot be accessed. Maintain the ESN data ofthe Trunking System following the new ESN.• When a new printed circuit board is used, the KenwoodESN changes, as does the Transceiver Information displayof the KPG-141D(C), but this does not have any effect onthe operation of the transceiver.• If changing to the original ESN, please contact our servicecenter.■ ESN Label LayoutKenwood ESN LabelNXDN ESN Label (Bar code)(Not used)NXDN ESN Label (Bar code)Kenwood ESN LabelNXDN ESN Label (Number)MPT ESN Label (Number)Cut lineNXDN ESN Label (12 digits)MPT ESN Label (10 digits)Note:A UPC code and UPC barcode is not printed on the Ken-wood ESN Label. If necessary, cut the label at the cut-offline and attach only the serial number.