(No.RA017)1-434.8 Common SectionItem Condition Measurement Adjustment Specifications/RemarksPanel tuningmodePC test mode Test-equip-mentUnit Ter-minalUnit Parts Method1.Setting1) DC voltage:13.6V2) SSG standard modulation[Wide] MOD:1kHz,DEV:3kHz[Narrow] MOD:1kHz,DEV:1.5kHz2.ReceiveAssist1) Adj item:[RAST]Adjust:[****]2) Adj item:[Low1 RAST]→[Low2 RAST]→[Low3 RAST]→[Low4 RAST]→[Low5 RAST]→[Low6 RAST]→[Center1 RAST]→[Center2 RAST]→[Center3 RAST]→[Center4 RAST]→[Center5 RAST]→[High1 RAST]→[High2 RAST]→[High3 RAST]→[High4 RAST]→[High5 RAST]→[High6 RAST]→Adjust:[****]Press [ ] keyto store the ad-justment val-ue.1) Adj item:[Receive Assist]2) Adj item:[Low1],[Low2],[Low3],[Low4],[Low5],[Low6],[Center1], [Center2],[Center3], [Center4],[Center5],[High1],[High2][High3],[High4][High5],[High6]Press [Apply All] but-ton to store the ad-justment value.Panel [Paneltuningmode][],[][PCtestmode][←],[→][PC test mode][Automatic Adjust-ment]1) Press [Tune AssistVoltage] button.2) Press [Apply All] but-ton to store the adjust-ment value after theautomatic adjustmenthas finished.[Manual Adjustment][V] indicator on the PCwindow shows VCO lockvoltage. Change the ad-justment value to getVCO lock voltage withinthe limit of the specifiedvoltage.Note:Confirm the VCO lockvoltage approximately3 seconds after theadjustment value ischanged.2.5V±0.1V[Automatic Ad-justment]After the automaticadjustment is per-formed, verify thatthe VCO lock volt-age is within thevoltage rangewhich is specifiedby the manual ad-justment.[Manual Adjust-ment]Press [Apply All]button to store theadjustment valueafter all adjustmentpoint have beenadjusted.Note:The assist adjust-ment value mustbe between from340 to 3550.