NXR-80034ADJUSTMENTTest Signaling■ AnalogNo. Decode tone Encode tone1 None None2 None 100Hz square wave3 QT 67.0Hz QT 67.0Hz4 QT 151.4Hz QT 151.4Hz5 QT 210.7Hz QT 210.7Hz6 QT 254.1Hz 1QT 254.1Hz7 DQT D023N DQT D023N8 DQT D754I DQT D754I9 None CWID encode (ID: VVV)10 None Single tone11 DTMF decode (Code: 159D) DTMF encode (Code: 159D)12 None DTMF encode (Code: 9)13 None Courtesy tone■ NXDNNo. Decode tone Encode tone1 RAN1 RAN12 RAN1 PN93 RAN1 Maximum deviation pattern• Signaling number 1 is used for link test with voice.• Signaling number 2 is used for TX modulation signal qual-ity test. i.e, TX adjacent channel power, FSK error, Occu-pied bandwidth, Emission mask, etc.• Signaling number 3 is used for TX deviation test. If themodulation mode is very narrow, the modulation fre-quency is 600Hz. If the modulation mode is narrow, themodulation frequency is 1200Hz.Flat cable (36-pin) about 256mm (E37-0979-05)ANT Jig for BPF adjustment (E30-3418-08)Fig. 1Fig. 2Fig. 3BPF center frequency (Production default): 390MHzPass bandwidth: ±2.5MHz at 3dBCenter frequency: 49.95MHzPass bandwidth: ±7.5MHz at 3dBCenter frequency: 49.95MHzPass bandwidth: ±3.75MHz at 3dB3dBmax.7.5kHzMorethan55dB30kHz 30kHz7.5kHzBPFMCF (Wide)MCF (Narrow)3dB max.2.5MHz 2.5MHz3dB max.3.75kHz3.75kHzMorethan35dBMorethan35dB12.5kHz 12.5kHz