RXD-251/301/351/371S/A3ITEM INPUTSETTINGSOUTPUTSETTINGSCASSETTE TAPEDECK SETTINGSALIGNMENTPOINT ALGN FOR F I G.ss otherwise specified : each ; switch should be set as follows : 0dBs = 0.775VT SW : OFFassette mechanism section (REC/PB head adjustment)Demagnetizationand cleaning – –Power OFF,demagnetization,cleaning playREC/PB head,erase head.capstan, pinchrollerDemagnetize the REC/PBhead by head eraser. Cleanthe REC/PB head, erasehead capstan and pinchroller with a cotton swabimmersed in alcohol.REC/PB headazimuthMTT-114,TCC-153SCC-172710 kHz, -10dB(A) PLAYAzimuthadjustmentscrewIn a setting wher the outputis maximized, adjust theazimuth adjustment screwso that the Lissajous figureappearing on the oscilloscopescreen comes near to a lineslanted45° Note : The headshould be installed in such amanner that it approaches thetape face.C board adjustmentTape speedMTT-111TCC-100SCC-17273 kHz, -4 dB(A) PLAY SFR201Adjust so that Frequency is3 kHz at the center of thetape.Playback level TCC-120315 Hz 0dB (A) PLAY Approx. -5dBmreference levelRecording levelPut standardtest tape(TCC-120)into B deck.Put standardblank tapeinto A deck.(A)Dubbing andplayback. Approx. -5dBmreference level13ADJUSTMENTSSETTE DECK SECTIONOscilloscopeFrequency counterAC voltmeter{ PIN2IC401(A)MAIN UNITTRUMENTS CONNECTION