TK-20005REALIGNMENT4. Clone modeProgramming data can be transferred from one trans-ceiver to another by connecting them via their SP/MIC con-nectors.Cloning can be performed as described below (the trans-mit transceiver is the source and the receive transceiver isthe target).The following data cannot be cloned.• Tuning data• Model name data• ESN data1. Turn the source transceiver and target transceiver powerOFF.2. Turn the source transceiver power ON while pressing the[PTT] and [Side] keys, to enter clone mode.3. Connect the cloning cable (part No. E30-3410-05) to theSP/MIC connectors on the source and target transceiv-ers.4. Turn the target transceiver power ON.5. Press the [Side] key on the source transceiver. The data ofthe source is sent to the target. While the source is send-ing data, red LED will light. While the target is receivingthe data, green LED will light. When cloning of data iscompleted, the source red LED turned off, and the targetautomatically operates in the User mode.6. Additional targets can be continuously cloned. Whenthe [Side] key on the source is pressed, the data of thesource is sent to the target again. Repeat steps 3 to 5 toclone additional transceivers.Note:• The Model name and Market codes must be the same inorder to clone the transceiver.• If the transceivers clone mode is configured as “Disabled”,the transceiver cannot enter clone mode.• If the Read authorization password is set to the trans-ceiver, the transceiver cannot enter to the clone mode.• Cannot be cloned if the password (overwrite password) isprogrammed to the target.Cloning cable(E30-3410-05)Fig. 2