TK-216025ADJUSTM ENTTest Equipment Required for AlignmentTest Equipment M ajor Specifications1. Standard Signal Generator Frequency Range 136 to 174M Hz.(SSG) M odulation Frequency modulation and external modulation.Output -127dBm/0.1μV to greater than -47dBm/1mV2. Pow er M eter Input Impedance 50Ω.Operation Frequency 136 to 174M Hz.M easurement Range Vicinity of 10W3. Deviation M eter Frequency Range 136 to 174M Hz.4. Digital Volt M eter M easuring Range 10mV to 10V DC(DVM ) Input Impedance High input impedance for minimum circuit loading.5. Oscilloscope DC through 30M Hz.6. High Sensitivity Frequency Range 10Hz to 1000M Hz.Frequency Counter Frequency Stability 0.2ppm or less.7. Ammeter 5A.8. AF Volt M eter Frequency Range 50Hz to 10kHz.(AF VTVM ) Voltage Range 1mV to 10V.9. Audio Generator (AG) Frequency Range 50Hz to 5kHz or more.Output 0 to 1V.10. Distortion M eter Capability 3% or less at 1kHz.Input Level 50mV to 10Vrms.11. Spectrum Analyzer M easuring Range DC to 1GHz or more12. Tracking Generator Center frequency 50kHz to 600M HzOutput Voltage 100mV or more13. 8Ω Dummy Load Approx. 8Ω, 3W.14. Regulated Pow er Supply 5V to 10V, approx. 3AUseful if ammeter equipped.■ The follow ing part s are required foradjustment1. Antenna connector adapterThe antenna connector of this radio uses an SM A terminal.Use an antenna connector adapter [SM A(f) – BNC(f) orSM A(f) – N(f)] for adjustment. (The adapter is not provided asan option, so buy a commercially-available one.)2. Repair Jig (Chassis)Use jig (part No.: A10-4082-03) for repairing the TK-2160.Place the TX-RX unit on the jig and fit it w ith screw s.The jig facilitates the voltage check and protects the finalamplifier FET w hen the voltage on the flow side of the TX-RXunit is checked during repairs.3. Battery Jig (W05-0909-00)+ Term inal (Red)– Term inal (Black)Connect the pow er cable properly betw een the battery jiginstalled in the transceiver and the pow er supply, and be sureoutput voltage and the pow er supply polarity prior to sw itchingthe pow er supply ON, otherw ise over voltage and reverseconnection may damage the transceiver, or the pow er supplyor both.When using the battery jig in user mode, the transceiverassumes that a lithium-ion battery pack is attached to thetransceiver. In adjustment mode, battery type detection isnot performed. Refer to page 10 for details.Note: When using the battery jig, you must measure thevoltage at the terminals of the battery jig. Otherw ise, a slightvoltage drop may occur w ithin the pow er cable, betw een thepow er supply and t he bat t ery jig, especially w hile t hetransceiver transmits.+ Term inal(Red)– Term inal(Black)C3100/25VC2470P/25VC1100P/25VR11.8M–S+Pow ersupplyPow er cableSCHEM ATIC DIAGRAM