TK-28014REALIGNMENT8-2. Channel Setting ModeThis is a mode for making channel settings with the panelkeys without using the FPU.Pressing [MON] when [SELF PROG] is displayed, setsChannel Setting Mode.Select an item set with [C] and change the selection with theencoder.The data displayed with [B] is stored in the memory andthen proceeds to the next item. Pressing [C] proceeds to thenext item without storing it in the memory.Press [MON] to set the display to [SELF PROG] and returnto reset (default) status.[MON] Beat shift yes/no[B]/[C][MON] RF Power High/Low[B]/[C][MON] Busy channel lockout yes/no[B]/[C][MON] Scan delete/add[B]/[C][MON] TX signalling[B]/[C][MON] TX frequency[B]/[C][MON] RX signalling[B]/[C][MON] RX frequency[B][MON] Channel set mode[MON]Self programming modeOFFOFF QTOFFOFFChannel selection Group selection[MON] Wide/Narrow[B]/[C][LAMP][LAMP] [LAMP]DQT N[LAMP][LAMP]DQT I[S][LAMP][LAMP][C]QT[LAMP]DQT N[LAMP][LAMP]DQT I[S][B]/[C]X57-5740Foil SideR134● Flow ChartItems set in Channel Setting Mode are as follows.Function settings Display RemarksChannel select CH or GRPRX Frequency RXF [LAMP] : Freq. On/Off switching[A] : 2.5kHz/5kHz/6.25kHz/7.5kHz/1MHz step switchingRX Signalling RXS [LAMP] : OFF/QT/DQT switching[A] : 1 step/Standard switching[S] : DQT Normal/Invert swtichingTX Frequency TXF Key operation same as RXFrequenciesTX Signalling TXS Key operation same as RXSignallingScan Del/Add SCN Delete/AddBusy Channel BSY YES/NOLockoutRF Power PWR HIGH/LOWBeat Shift SFT YES/NOWide/Narrow W/N Wide/NarrowFig. 3