TK-316025ADJUSTMENTCommon SectionItem Condition Measurement Adjustment Specifications/Test equipment Terminal Parts Method Remark1.Setting 1) BATT terminal votage:7.5V2) SSG standard modulation[Wide 5k] MOD:1kHz,DEV:3kHz[Wide 4k] MOD:1kHz,DEV:2.4kHz[Narrow] MOD:1kHz,DEV:1.5kHz2.VCO lock 1) CH:High Power meter ANT TC2 ADJ 3.5V ±0.2V (X2)voltage DVM CV 3.2V ±0.2V (E)RX 2) CH:Low Check 0.6V or more3.VCO lock 3) CH:High TC1 ADJ 3.5V ±0.2V (X2)voltage PTT:ON 3.2V ±0.2V (E)TX 4) CH:Low Check 0.6V or morePTT:ON[Wide 4k] is only E market.1.Frequency 1) CH:Center Frequency counter ANT VR1 Center frequencyAdjust 2) PTT:ON ±50Hz[Wide 5k]2.High power TEST CH: Low Power meter Programming 4.0W ±0.1WAdjust Low’ Ampere meter Software:KPG-82D 2.0 A or less[Wide 5k] CenterHigh’High(5 points)BATT terminal voltage:7.5VPTT:ON3.Low power TEST CH: Low 1.0W ±0.1WAdjust Low’ 1.0 A or less[Wide 5k] CenterHigh’High(5 points)BATT terminal voltage:7.5VPTT:ON4. Max deviation TEST CH: Low Power meter ANT 4.2kHz ±50HzAdjust Center Dev meter SP/MIC connector (According to[Wide 5k] High Oscilloscope the lager +,–)(3 points) AGAG:1kHz/150mV AF VTVMDev meter filterLPF:15kHzHPF:OFFPTT:ON[Wide 4k] TEST CH: Center 3.4kHz ±50HzPTT:ON (According to the lager +,–)[Narrow] 2.1kHz ±50Hz(According to the lager +,–)5.VOX 1 TEST CH: Center Power meterWriting AG:1KHz/60mV Dev meter[Wide 5k] OscilloscopeAGAF VTVM6.VOX 10 TEST CH: CenterWriting AG:1KHz/4.0mV[Wide 5k]Transmitter SectionItem Condition Measurement Adjustment Specifications/Test equipment Terminal Parts Method Remark