TK-318025Item ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal PartsUnit MethodADJUSTMENT• Wide 5k 5) Adj item : [w SQLT] SSG Panel ANT Panel Selector After input signal After adjusting SQL, checkAdjust : [✳✳✳] knob from SSG, press [B] SQL open/close.SSG output : –113dBm (0.5μV) AF VTVM Universal key. That numeric SSG –113dBm : Open(MOD : 1kHz/± 3.0kHz) Oscilloscope connector will be stored in SSG OFF : Closememory. [nC SQLT] MOD 1kHz/± 1.5kHz6) Adj item : [wL SQLT] → [sC SQLT] MOD 1kHz/± 2.4kHz[wC SQLT] → [wH SQLT] [wC SQLT] MOD 1kHz/± 3.0kHzAdjust : [✳✳✳]8. High RSSI 1) Adj item : [n HRSSI]adjust Adjust : [✳✳✳]• Narrow SSG output : –70dBm(MOD : 1kHz/± 1.5kHz)2) Adj item : [nL HRSSI] →[nC HRSSI] → [nH HRSSI]Adjust : [✳✳✳]• Wide 4k 3) Adj item : [s HRSSI]Adjust : [✳✳✳]SSG output : –70dBm(MOD : 1kHz/± 2.4kHz)4) Adj item : [sL HRSSI] →[sC HRSSI] → [sH HRSSI]Adjust : [✳✳✳]• Wide 5k 5) Adj item : [w HRSSI]Adjust : [✳✳✳]SSG output : –70dBm(MOD : 1kHz/± 3.0kHz)6) Adj item : [wL HRSSI] →[wC HRSSI] → [wH HRSSI]Adjust : [✳✳✳]Adjustment PointsTC1 TC2 ANTCVTX-RX unitFoil side view