TK-318035Item ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal PartsUnit MethodADJUSTMENT16. DTMF 1) Adj item : [n DTMF] Power meter Panel ANT Panel Selector 1.25kHz ± 0.1kHzdeviation Adjust : [✳✳✳] knobadjust Deviation meter filter Deviation Universal• Narrow LPF : 15kHz meter connectorHPF : OFF OscilloscopePTT : ON AGAF VTVM• Wide 4k 2) Adj item : [s DTMF] 2.0kHz ± 0.1kHzAdjust : [✳✳✳]PTT : ON• Wide 5k 3) Adj item : [w DTMF] 2.5kHz ± 0.1kHzAdjust : [✳✳✳]PTT : ON17. MSK 1) Adj item : [n MSK] 1.5kHz ± 0.1kHzdeviation Adjust : [✳✳✳]adjust Deviation meter filter• Narrow LPF : 15kHzHPF : OFFPTT : ON• Wide 4k 2) Adj item : [s MSK] 2.4kHz ± 0.1kHzAdjust : [✳✳✳]PTT : ON• Wide 5k 3) Adj item : [w MSK] 3.0kHz ± 0.1kHzAdjust : [✳✳✳]PTT : ON18. TONE 1) Adj item : [n TONE] 1.5kHz ± 0.1kHzdeviation Adjust : [✳✳✳]adjust Deviation meter filter• Narrow LPF : 15kHzHPF : OFFPTT : ON• Wide 4k 2) Adj item : [s TONE] 2.4kHz ± 0.1kHzAdjust : [✳✳✳]PTT : ON• Wide 5k 3) Adj item : [w TONE] 3.0kHz ± 0.1kHzAdjust : [✳✳✳]PTT : ON19. BATT 1) Adj item : [BATT] Power meter Panel ANT Panel After pressing the BATT terminal voltage : 5.8Vdetection Adjust : [✳✳✳] PTT switch, confirmwriting PTT : ON DVM BATT that one predeter-terminal mined numeric inthe range 1 to 256appears and thenpress [B] key. Thatnumeric will bestored in memory.