TK-38044ADJUSTMENTItem Condition Measurement Adjustment Specifications/Test equipment Unit Terminal Unit Parts Method Remark7. Max DEV 1) Adj item [MAX] Power meter Panel ANT Panel Encoder 3.8kHz ±50HzAdjust Adjust [∗∗∗] Dev meter Universal knob (According to[Wide] AG:1kHz / 150mV Oscilloscope connector the larger +,-)Dev meter filter AGLPF:15kHz AF VTVMHPF:OFF2) Adj item[L MAX] ➞ [C MAX] ➞ [H MAX]Adjust [∗∗∗]PTT:ON[Narrow] 1) Adj item [n MAX] 1.75kHzAdjust [∗∗∗] (According toPTT:ON the larger+,-)8. MIC [Panel Test Mode] Check 2.2~3.0kHzSensitivity 1) CH-Sig:1-1Check AG:1kHz / 15mVLPF:15kHzPTT:ON9. DQT Balance 1) Adj item [BAL] Power meter Panel ANT Panel Encoder Make theAdjust Adjust [∗∗∗] Dev meter Universal knob demodulation[Wide] LPF:3kHz Oscilloscope connector waves intoHPF:OFF AG square waves.2) Adj item AF VTVM[L BAL] ➞ [C BAL] ➞ [H BAL]Adjust [∗∗∗]PTT:ON[Narrow] 3) Adj item [n BAL]Adjust [∗∗∗]PTT:ON10. QT Deviation 1) Adj item [FQT] Wide:0.75kHz ±50HzAdjust Adjust [∗∗∗] Narrow:0.35kHzLPF:3kHzHPF:OFF[Wide] 2) Adj item[L FQT] ➞ [C FQT] ➞ [H FQT]Adjust [∗∗∗]PTT:ON[Narrow] 3) Adj item [n FQT]Adjust [∗∗∗]PTT:ON11.DQT 1) Adj item [FDQT]Devition Adjust [∗∗∗]Adjust LPF:3kHzHPF:OFF[Wide] 2) Adj item[L FDQT] ➞ [C FDQT] ➞ [H FDQT]Adjust [∗∗∗]PTT:ON[Narrow] 3) Adj item [n FDQT]Adjust [∗∗∗]PTT:ON[Panel Tuning Mode except when Panel TEST Mode is specified.]