TK-7302/7302( V ) /7302H/7302H ( V )31ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications / RemarksTest-equipment Unit Terminal Unit Parts Method3. Low Power(Auto)(Narrow)1) CH: TX lowCH: TX low’CH: TX centerCH: TX high’CH: TX highTransmitPowermeterANT FPU 5W ±0.5W4.0A or less4. DQTBalance(Wide)1) CH: TX lowCH: TX low’CH: TX centerCH: TX high’CH: TX highDeviation meter filterLPF: 3kHzHPF: OFFTransmitDeviationmeterOscillo-scopeThe Deviation of20Hz frequency isfi xed.Change the 1kHzadjustment value tobecome the samedeviation of 20Hzwithin the specifiedrange.±0.4dB5. MaximumDeviation(Wide)1) CH: TX lowCH: TX low’CH: TX centerCH: TX high’CH: TX highDeviation meter filterLPF: 15kHzHPF: OFFAG: 1kHz/50mVTransmitDeviationmeterOscillo-scopeAGAFVANTMIC4.2kHz(According to thelarge +, –)±0.1kHz6. MICsensitivity1) CH: TX centerAG: 1kHz/5mVTransmitCheck 2.2kHz~3.6kHz7. DQTDeviation(Wide)1) CH: TX centerDeviation meter filterLPF: 3kHzHPF: OFFTransmitFPU 0.75kHz ±0.05kHz8. QTDeviation(Wide)1) CH: TX centerDeviation meter filterLPF: 3kHzHPF: OFFTransmit0.75kHz ±0.05kHz9. DTMFDeviation(Wide)1) CH: TX centerDeviation meter filterLPF: 15kHzHPF: OFFTransmit3.0kHz ±0.1kHz10. MSKDeviation(Wide)1) CH: TX centerDeviation meter filterLPF: 15kHzHPF: OFFTransmit3.0kHz ±0.1kHz