TK-8100H30Test Equipment Required for AlignmentTest Equipment Major Specifications1. Standard Signal Generator Frequency Range 400 to 520MHz(SSG) Modulation Frequency modulation and external modulationOutput –127dBm/0.1μV to greater than –7dBm/100mV2. Power Meter Input Impedance 50ΩOperation Frequency 400 to 520MHz or moreMeasurement Capability Vicinity of 100W3. Deviation Meter Frequency Range 400 to 520MHz4. Digital Volt Meter Measuring Range 1 to 20V DC(DVM) Accuracy High input impedance for minimum circuit loading5. Oscilloscope DC through 30MHz6. High Sensitivity Frequency Range 10Hz to 1000MHzFrequency Counter Frequency Stability 0.2ppm or less7. Ammeter 20A8. AF Volt Meter Frequency Range 50Hz to 10kHz(AF VTVM) Voltage Range 1mV to 3V9. Audio Generator (AG) Frequency Range 20Hz to 20kHz or moreOutput 0 to 1V10. Distortion Meter Capability 3% or less at 1kHzInput Level 50mV to 10Vrms11. 4Ω Dummy Load Approx. 4Ω, 10W or more12. Regulated Power Supply 13.6V, approx. 20A (adjustable from 9 to 17V)Useful if ammeter requipped13. Spectrum Analyzer Center frequency 50KHz to 600MHz14. Tracking Generator Output Voltage 100mV or moreTuning cable (E30-3383-05)Adapter cable (E30-3383-05) is required forinjecting an audio if PC tuning is used.See “PC Mode” section for the connection.MIC connector(Front view)Test cable for microphone input (E30-3360-08)1 : BLC2 : PSB3 : E4 : PTT5 : ME6 : MIC7 : HOOK8 : CMADJUSTMENTLead wire +MICShield wire –3245678312456781 GREENREDBLACKBLUESHIELDWHITEGRAYYELLOWPTTEMIC-EMICHK18Test Frequency (MHz)Channel TX RX1 : Center 470.100 470.0502 : Low 450.100 450.0503 : High 489.900 489.9504 470.000 470.0005 470.200 470.2006 470.400 470.400