ADJUSTMENTMeasurementTest-equipment Unit TerminalAdjustmentUnit Parts Method Specifications/RemarksConditionItem24TK-868HG1. Frequency 1) Set test mode Power meter Rear ANT Front CH / Check 470.100MHz±100Hz CSelect “FREQ” in tuning mode. F. counter panel panel 415.100MHz±100Hz C3PTT : ONAdjust [_**]2. Power 1) Maximum power Check More than 42.0Woutput Set test modeSelect “HPOW” in tuning mode.“H.POW”Adjust [256]PTT : ON3. High power 1) Set test mode 40.0W ± 2.0WSelect “HPOW” in tuning mode.“H.POW”PTT : ONAdjust [***]2) “H.P.OW”PTT : ONAdjust [***]3) “H.P.O.W”PTT : ONAdjust [***]4) “H.P.O.W.”PTT : ONAdjust [***]5) “H.P.O.W._.”PTT : ONAdjust [***]4. Low power 1) Set test mode Power meter 10.0W ± 1.0WSelect “LPOW” in tuning mode.“L.POW”PTT : ONAdjust [***]2) “L.P.OW”PTT : ONAdjust [***]3) “L.P.O.W”PTT : ONAdjust [***]4) “L.P.O.W.”PTT : ONAdjust [***]5) “L.P.O.W._.”PTT : ONAdjust [***]5. Power check 1) Set test mode Power meter ANT Check 40W±2WCH : CH1 - Sig1 12A or lessCH2 - Sig1 Ammeter DC INCH3 - Sig1PTT : ONTransmitter Section26