69Software 09■ Controlling the TS‑890S from a Remotely‑placed PC● System configurations that are configured by using the ARCP‑890 and TS‑890SSignal Type PC ConnectionMethodHost Station(TS‑890S)Software Hardware Software HardwareControlsignal ARCP-890 -Network - Connect to theLAN connector.Audio signalARCP-890 andWindows sounddriverMicrophone andspeaker connectedto a PCNote:◆ Configure “On (Internet)” in “KNS Operation (LAN Connector)” of the TS-890S.● System configurations that are configured by using the ARCP‑890, ARHP‑890, and TS‑890S (for the KNS connection via LAN)Signal Type PC ConnectionMethodHost Station(PC placed on theTS‑890S side)Software Hardware Software HardwareControl signal ARCP-890 -Network ARHP-890 Connect to the LANconnector.Audio signalARCP-890 andWindows sounddriverMicrophone andspeaker connectedto a PCNote:◆ Configure “On (Internet)” in “KNS Operation (LAN Connector)” of the TS-890S.● System configurations that are configured by using the ARCP‑890, ARHP‑890, ARVP‑10,and TS‑890S (for the KNS connection via Internet)Signal Type Remote Station (Remote PC) ConnectionMethodHost Station(PC placed on the TS‑890Sside)Software Hardware Software HardwareControlsignalARCP-890 - Network ARHP-890 Connect to the LANconnector, USB‑Bconnector, or COMconnector.Audio signal ARVP-10R orgeneral VoIPsoftwareMicrophone andspeaker connectedto a PCARVP-10H orgeneral VoIPsoftwareConnect to the ACC 2connector or USB‑Bconnector.Note:◆ Configure “On (Internet)” in “KNS Operation (LAN Connector)” of the TS-890S.◆ When the ARHP-890 and TS-890S are connected by a USB-B connector or COM connector, the bandscope screenrefreshes at a slower speed.◆ Even when the USB‑B connector is used for audio signal I/O on the host station side, the ARUA-10 is not used