Mechanical safetyMechanical safetyFlown congurationsThe Kiva rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the guidelinesof BGV-C1.2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described inthis manual achieve a safety factor of 4 or higher.Refer to Soundvision for the safety factor of a specic deployment.The safe limit gives the maximum number of elements for which the safety factor is compliant with the 2006/42/EC: Machinery Directive, within the use dened in this manual and regardless of the other deployment parameters (siteangles, inter-enclosure angles, etc.).The maximum limit gives the maximum number of elements for which the safety factor can be compliant with the2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.For mixed arrays refer to your Soundvision model.Kivaconguration rigging accessory safe limit maximum limitown KIBU-SB 8 20own KIBU 8 20ceiling-mounted KIET 2SB15mconguration rigging accessory maximum / Safe limitown KIBU-SB 8Other congurationsFor other congurations, respect the recommended maximum limit for optimal stability.Kivaconguration rigging accessory safe limit maximum limitstacked KIBU-SB 4 9pole-mounted KIET + 35 mm pole 2pole-mounted KIET + 35 mm pole + SB15m 2SB15mconguration rigging accessory maximum / safe limitground-stacked no rigging accessory 4SB18 / SB18i / SB18mconguration rigging accessory maximum / safe limitground-stacked no rigging accessory 410 Kiva owner's manual (EN) version 1.0