Flown array options and site angle settingFlown array options and site angle settingUsing M-BUMPM-BUMP rigging optionsL-Acoustics recommends 5 different rigging options to y the M-BUMP for arrays containing Kara and/or SB18enclosures. It is possible to use 0, 1, or 2 M-BAR and 1 or 2 rigging points (see gure below).Always refer to the mechanical data and warning indications provided in Soundvision Software (MechanicalData section) to verify the mechanical conformity of the loudspeaker system before installation.Option 1: 0 M-BAR, 1 point1 motor3 positions (front, center, rear)Option 2: 0 M-BAR, 2 points2 motorsFixed front and rear positions(spacing = 400 mm/15 inch)Option 3: 1 M-BAR, 1 point1 motorVariable position (see M-BUMP site angle setting(p.190))Left view = rear extension congurationRight view = front extension congurationOption 4: 1 M-BAR, 2 points2 motorsFixed front and rear positions(spacing = 900 mm/35 inch)Left view = rear extension congurationRight view = front extension congurationOption 5: 2 M-BAR, 2 points2 motorsVariable position from front to rearSame hole number for both points [8.2.2](spacing = 663 mm/26 inch)Left view = rear extension congurationRight view = front extension congurationKara owner's manual (EN) version 1.0 189