LA4X Amplified Controlleruser manualVERSION 4.0LA4X_UM_EN_4.0 w w w . l - a c o u s t i c s . c o m 20The table below describes the maximum number of enclosures a single LA4X amplified controller can drive.Table 4: Maximum number of enclosures per LA4XTechnology LoudspeakerenclosureMax number of connectionsper output *Max number of enclosuresper controllerCoaxial5XT 4 168XT 2 8Passive 12XT 1 4Active 12XT 2 4115XT HiQ 1 2ConstantCurvature WSTARCS® WIDE/FOCUS 1 4ARCS® II 1 2Variable CurvatureWSTKIVA KILO 2 8KARA® 2 4KUDO® 1 1K2 1 1Subwoofers SB15m 1 4SB18 1 4* For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output.For active loudspeakers, the value corresponds to the number of sections in parallel on the output.3.4.5 L-NET cablingThe LA4X can be remote controlled over an Ethernet network (called L-NET) using LA NETWORK MANAGERsoftware (refer to the LA NETWORK MANAGER video tutorial).To connect the LA4X to L-NET use the EtherCON connectors on the L-NET panel (see Figure 7). Each of the twoEtherCON connectors can be equally used as an IN or LINK connector.Refer to the LA NETWORK MANAGER video tutorial for network setup (type of cables, physical connections,network topology, etc.).