InstallationVentilationTo maintain moderate operating temperatures, the LA4X is equipped with two fans providing front to rear airow.Ventilation instructionsInstall the controller in an open area so that the front and rear panels are located at a minimum distance of 30 cmfrom any external object or structure.Ensure the front foam lter is clean and dirt free.Do not block the front and rear ventilation grills.Ventilation when rack-mountedDo not block the ventilation grills with front or back panels or doors. If not possible, use a forced-ventilationsystem.When stacking more than one controller in a rack, mount them directly on top of each other or close any openspace in the rack with blank panels.Connecting to AC mainsElectrical specicationsAC mains specicationsVerify the electrical conformity and compatibility of the mains supply.Only connect the product to an AC power outlet rated 100-240 V, 50-60 Hz, with the following current values:100-120 V: 20 A200-240 V: 10 AWARNING: The product is of CLASS 1 construction and shall be connected to a mains socket outlet with aprotective connection to earth.Three-phase circuitWhen the product is used in a three-phase circuit, verify the electrical conformity andcompatibility of the three-phase circuit.Verify that the three phases work, and balance the loads between the three phases.Verify that the neutral and earth work.Never try to emulate a 230 V circuit connecting an apparatus to two live wires of a 120 V three-phase circuit.Never try to emulate a 200 V circuit connecting an apparatus to two live wires of a 100 V three-phase circuit.Circuit breakerAlways interconnect a Class C circuit breaker between the product and the mains supply.The circuit breaker current rating depends on the mains voltage rating, as follows:100-120 V: 20 A200-240 V: 10 A15 LA4X user manual (EN) version 9.1