Front Panel Interface23Lake LM Series Operation Manual Rev 1.3.5Module input mutes are only available in Contour Mode; Module input mutes are not applicable in MesaMode. The quantity and position of the output mute buttons changes as shown in Figure 6-4 depending onwhether the device is configured in Contour Mode (six outputs) or Mesa Mode (four outputs).Please refer to the Lake Controller Operation Manual for details of Module mute controls via the software.6.8.2 Clip IndicationThe dedicated 5-segment metering LEDs (Figure 6-4 ) display Module input and output clip or pre-clipconditions. Additionally, the faults and warnings LED described in section 6.7.2 provides clip warnings forinput mutes, or GPIO protective mutes, along with confirmation text on the LCD screen.Clipping is monitored at the following positions in the signal chain:▸ Analog Inputs: If the input signal exceeds either +12 dBu or +26 dBu (according to analog sensitivitysetting), a clip indication will be given. This does not apply if digital inputs are selected.▸ Module Inputs: If the signal level at this point exceeds +25 dBu, a clip indication will be given.▸ Module Outputs: If the signal level at this point exceeds +21 dBu, a clip indication will be given.6.9 Meter Mode6.9.1 Home View (Contour Mode)The default view when powering on an LM Series device device configured in Contour Mode is the MeterMode > Home View as shown in Figure 6-7.Figure 6-7: Meter Mode > Home ViewHome View (Contour Mode) provides a summary of Module I/O gain level and limiter gain reduction, alongwith frame, module and channel labeling information.