Model 4500 Premier Dust and Opacity Monitor50↑↓↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵B2-2 Output SetupOpacity: 0.0%Faults: ↑↓ ↵↵↵↵↵Opacity: 0.0%Setup: ↑↓ ↵↵↵↵↵Opacity: 0.0%Outputs: ↑↓ ↵↵↵↵↵Opacity: 0.0%Output 1: ↑↓ ↵↵↵↵↵Outputs 1: ↑↓ ↵↵↵↵↵OpacityOutputs 1: ↔ ↵↵↵↵↵OpacityThe Model 4500 Premier Dust and Opacity Monitor has two independentcustomer outputs available. Each signal output interval may be altered bysetting the ‘Average 1’ and ‘Average 2’ displays accordingly.1. Press and hold the maintenance key for a period of 3 seconds,until the red LED illuminates.2. Scroll through the menu spine using the ↑ and ↓ keys until‘SETUP’ is displayed then press the ‘ENTER’ (↵) key.3. The word ‘Outputs’ is now displayed (if not use the ↑ and ↓ keysto scroll through the menu until ‘Outputs’ is displayed). Nowpress the ‘ENTER’ (↵) key.4. The word ‘Output 1’ is now displayed (if not use the ↑ and ↓ keysto scroll through the menu until ‘Output 1’ is displayed). Press the‘ENTER’ (↵) key and the ‘Opacity’ option is displayed (this mayvary if previously altered), press the ‘ENTER’ key again (notice theunderlined character).Continue to step 5.