10Base-T/100Base-TX/E1 converterOperating Manual_______________________________________________________________________________IOA78-1C 33 January 20056.3. Environmental requirements6.3.1. OperationThe converter may operate indoors, in unevenly heated rooms, in the following ambientconditions:Environmental parameter Acceptable valueAmbient temperature +5 ÷ +40OCAir relative humidity ≤ 80% at a temperature of +20 OC6.3.2. TransportThe devices in factory packaging should be transported in the following conditions:Environmental parameter Acceptable valueAmbient temperature -25 ÷ +40OCTemperature variation rate ≤ 10OC/hMaximum air humidity 95%Atmospheric pressure 700 ÷ 1060 hPaMultiple strokes 5 ÷ 15 g in 10 ms6.3.3. StorageConverters should be stored indoors, in the following ambient conditions:Environmental parameter Acceptable valueAmbient temperature -25 ÷ +55OCHumidity 5% to 90% over +40OCVibrations frequency: 10 Hz to 55 Hz, amplitude: 0.15 mmduration: 10 cycles in three planesLevel of pollution typical home or office environment6.4. Electromagnetic compatibilityConverters conform to requirements for A class devices regarding radio/electrical interferenceas set out in the PN-EN 55022 standard, provided that they have been installed in accordance withthis manual.Warning:This is a Class A device. In a domestic environment this product may cause radio and electrical interferencein which case the user may be required to take adequate measures.6.5. Power SupplyParameter ValueRated supply voltage 4,5÷5,5 V; 0 HzMaximum rated power input 800 mAType of connection double clamped (screwed) joint