730 Dosimeter Reference Manual Setting a Visual Alarm on the Spartan 730 53Section 6 Dosimeter Settings ReferenceThis section provides a complete reference for all settings available onthe Spartan 730 Dosimeter. Depending on the options you purchased,some settings listed here may not be available.6.1 Setting a Visual Alarm on the Spartan 730 ................................................. 536.1.1 Enabling Dosimeter 1 Alarm 1 ............................................................................... 546.1.2 Selecting Alarm Options ........................................................................................ 556.2 Setting Up a Measurement Timer ............................................................... 576.2.1 Setting a Timed Stop Measurement Timer ........................................................... 576.2.2 Setting a Daily Measurement Timer ...................................................................... 586.2.3 Using Merge Files On the Dosimeter ..................................................................... 606.2.4 Disabling a Measurement Timer ........................................................................... 606.3 Setting Event Sound Recording Options .................................................... 616.4 Customizing Frequency Weight and Detector Settings ............................. 626.4.1 Setting the Frequency Weight ............................................................................... 636.4.2 Setting the Peak Frequency Weight ...................................................................... 636.4.3 Setting the Detector ............................................................................................... 646.5 Customizing the Meter Options .................................................................. 646.5.1 Naming the Dosimeter ........................................................................................... 646.5.2 Enabling Time History ........................................................................................... 656.5.3 Disabling Octave Band Analysis On the Dosimeter .............................................. 666.5.4 Setting a Custom Noise Level Increment .............................................................. 676.6 Setting Date and Time Manually On the Meter .......................................... 686.7 Customizing the Meter Preferences ........................................................... 696.7.1 Setting Your Decimal Preference .......................................................................... 696.7.2 Setting the Language On the Dosimeter .............................................................. 706.7.3 Disabling or Enabling Auto Shut Off ...................................................................... 706.1 Setting a Visual Alarm on the Spartan 730The Spartan 730’s visual alarm settings enable you and the worker tobe aware of milestones within the current noise exposure period. TheDosimeter 1 setting comes with 2 customizable visual alarm settings:Alarm 1, Alarm 2.First, enable the alarm, then choose the alarm Source and Levels(noise exposure metric and levels) to base the alarm on. Each alarmhas an action level and a limit level alarm. These levels are selectablefrom 70 to 100 dB. The alarm state is active while the measured soundpressure level is above the set alarm level. The alarm deactivateswhen the measured sound pressure level drops below the alarm level.