Programmable DC Power Supply User’s Guide16Chapter 3 Programmable InterfacePress 【RMT】to enter remote control mode.3.1 To set the series portBaud Rate: 9600, Check: No parity, Word Length: 8, Stop bit: 13.2 Programmable CommandsSCPI Commands Description*IDN? Query the device identificationReturn HA-PSA3515,BJA5.297.556, firmwareversionSYSTem:VERSion? Query the device firmware version, Return theversion number:LOCal To set local control mode, return 1VOLTage To set output voltageMINimumMAXimum:PROTection :CLEarCURRent MINimumMAXimumOUTPut OFFONOUTPut?MEASure?MEASure:CURRent?:MINimum?:MAXimum?To output minimum voltageTo output maximum voltageTo set OVPTo clear the OVPTo set output currentTo output minimum currentTo output maximum currentTurn off the outputTurn on the outputQuery output status, Return 1, 0Query all voltage/currentQuery currentQuery minimum currentQuery maximum current:VOLTage?MINimum?:MAXimum?:PROTection?Query voltageQuery minimum voltageQuery maximum voltageQuery OVP value