R e c h a r g e a b l e F l a s h l i g h t MR Rev.1 8/03 3421-000-438RECHARGEABLE SWITCH REPLACEMENTRechargeable FlashlightTools Required:1. Barrel Holder2. Spanner Wrench3. Multimeter1. Bulba. Verify that you have a good LAMP andBATTERY PACKProbe placement• Place red probe on one lamp pin• Place black probe on the other lamp pin (it makes nodifference which probe goes to what pin)• If the lamp is good you will get a (000) reading• A (1.) is a bad lamp2. Batterya. Warranty – 12months from thefour numberDATE CODE onthe battery pack(0324). First two numbers (03) indicateyear Second two numbers (24) indicateweek of year.b. Battery Damage. Look for:1). Signs of gas or chemical leakage.2). Discoloration.3). Fuzzy material near positive button.4). Bulging or deformation.5). Charge for 15 minutes prior to test.6). Test.Battery TestMeter SettingsDial set at V-20 VoltsProbes: Black in“COM” portRed in “VΩmA” port.Testing Procedures(Troubleshooting)1. Bulb 2. Battery 3. Charge Module 4. Converter 5. Circuit Board