Contents - contact information
- important safety instructions
- Table Of Contents
- Table Of Contents
- Introduction
- Features and Benefi ts
- Figure 1-1, Power Switch, Status LED and Accessory Connection Ports
- Figure 1-3, Left Side Features
- How an Inverter/Charger Works
- Appliances and Run Time
- Installation
- Figure 2-1, Simplifi ed Installation Diagram for Permanent Installations
- Figure 2-2, Approved Mounting Positions
- Figure 2-3, MS Series Dimensions
- Wiring the Inverter - General Requirements
- DC Wiring
- Figure 2-4, DC and Battery Temperature Sensor Wiring
- Table 2-1, Recommended DC Wire/Overcurrent Device for Rated Use
- Figure 2-5, Battery Hardware Installation
- Figure 2-7, Battery Temperature Sensor
- AC Wiring
- Figure 2-8, MS Series Inverter/Charger - AC Wiring
- Figure 2-10, AC Terminal Block
- Table 2-3, AC Input/Output Wiring Confi gurations
- Figure 2-11, AC Wiring for Single In - Single Out (30 A) Confi gurations
- Figure 2-12, AC Wiring for Single In - Single Out (60 A) Confi gurations
- Figure 2-13, AC Wiring for Single In - Dual Out Confi gurations
- Figure 2-14, AC Wiring for Dual In - Single Out Confi gurations
- Figure 2-15, AC Wiring for Dual In - Dual Out Confi gurations
- Figure 2-16, Grounding System for MS Series
- Figure 2-17, Multiple Connections to DC Ground Rod (Method 1)
- Figure 2-18, Multiple Connections to DC Ground Rod (Method 2)
- Table 2-5, Equipment Grounding Conductor Sizing
- Figure 2-20, Neutral-to-Ground Connection (Inverter Mode)
- Figure 2-22, Disconnecting the Ground-to-Neutral connection
- Final Inspection
- Functional Test
- Operation
- Figure 3-2, Power Flow - Standby Mode
- Figure 3-3, Automatic 4-Stage Charging Graph
- Figure 3-4, BTS Temperature to Charge Voltage Change
- Protection Circuitry Operation
- Figure 3-5, Power Switch and Status Indicator
- Table 3-2, Inverter/Charger Default Values
- Maintenance and Troubleshooting
- Troubleshooting
- Resetting the Inverter
- Appendix A - Specifi cations and Optional Equipment
- A-2 Inverter Effi ciency
- A-4 Optional Equipment and Accessories
- Appendix B - Battery Information
- B-5 Battery Bank Sizing Worksheet
- B-6 Battery Wiring Confi gurations
- Figure B-4, Battery Bank Wiring Examples (12-volt)
- Limited Warranty
|
Page 25© 2009 Magnum Energy Inc.InstallationM a in P a n e l( U tility /G e n e ra to r In p u t )M S S e rie s In v e rte rA C T e rm in a l B lo c k( A C in p u t a n d o u tp u t w irin g )S IN G L E IN / S IN G L E O U T (3 0A ) w irin gA C H O T 1 IN( from M a in P a nel)A C H OT 1 OU T(to S ub P ane l)A C N E U T IN( from M a in P a nel)A C N EU T O U T(to S ub P ane l)S u b P a n e l a n d O u tle ts(In v e rte r L o a d s )1 2 0V A C1 2 0V A CA C G R O U N D S(to /from bothP a ne ls)ONOFFO NO FFO NO F FO NO F FO NO FFO NO FFO NO F FO NO F FO NO FFO NO FFO NO F FO NO FFO NO F F3 0M axim um30 am p breaker(single pole )required toinverter AC inputIn M obile installations : neutral is typically notconnected to ground In m ain panel.O NO FFO NO F FONOFFFigure 2-11, AC Wiring for Single In - Single Out (30 A) Configurations
PreviousNext |