[3] DISASSEMBLY/ASSEMBLY[3]-9. Front arm sectionDISASSEMBLINGASSEMBLINGDISASSEMBLINGRefer to Fig. 55.1) Loosen M6x8 Hex. socket set screw (2pcs.) on Pipeholder and remove Pipe holder.2) Loosen M6x18 Thumb screw and pull out Frontarm complete straightly in the direction designated withwhite arrow to prevent the pipes from being stuck.Take the disassembling step in reverse.1) Loosen Lever 105 by turning counterclockwise. (Fig. 56)2) Remove M4x10 Pan head screw and then remove Lever 105. (Fig. 57)3) Remove M10 Hex bolt and Flat washer 10. (Fig. 57)4) Remove M10-17 Hex lock nut using Box wrench 17.Flat washer 10 (2pcs.) and Thrust needle cage 1024 can be removed as drawn in Fig. 58.5) Remove Arm section from Arm holder complete. (Fig. 59)6) Remove Retaining ring S-12 from the groove on Arm using 1R291.Stopper, Flat washer 12 and Torsion spring 14 can be removed. (Fig. 60)Remove CT 4x16 Tapping screw (3pcs.) Pointer and Arm cover. (Fig. 60)Fig. 55Fig. 56Fig. 59Fig. 57 Fig. 58Fig. 60P 18/ 35R epairM6x8 Hex. socketset screw (2pcs.)Pipe holderFront armcompletePipes of Front arm completeM6x18 Thumb screw[3]-10. Arm complete, Arm holderLever 105Arm sectionArm coverPointerArm holder completeGroove on Arm forfitting Retainer ring S-12 Retainer ring S-12Flat washer 12Torsionspring 14StopperCT 4x16Tapping screw(3pcs.)Lever 105M4x10 Panhead screwM10 Hex boltFlat washer 10M10-17Hex lock nutThrust needle cage 1024Flat washer 10