Installation Instructions Section 22-2Location of Ice MachineThe location selected for the ice machine must meetthe following criteria. If any of these criteria are notmet, select another location.• The location must be free of airborne and othercontaminants.• The air temperature must be at least 35°F (1.6°C),but must not exceed 110°F (43.4°C).• The location must not be near heat-generatingequipment or in direct sunlight.• The location must not obstruct air flow through oraround the ice machine. Refer to the chart belowfor clearance requirements.Water-CooledTop/Sides 24" (609 mm)*Back 24" (609 mm)**There is no minimum clearance required. This valueis recommended for efficient operation and servicingonly.Leveling the Ice Storage Bin1. Screw the leveling legs onto the bottom of thebin.2. Screw the foot of each leg in as far as possible.CAUTIONThe legs must be screwed in tightly to preventthem from bending.3. Move the bin into its final position.4. Level the bin to assure that the bin door closesand seals properly. Use a level on top of the bin.Turn each foot as necessary to level the bin.5. Inspect bin gasket prior to ice machineinstallation. (Manitowoc bins come with a closedcell foam gasket installed along the top surface ofthe bin.)6. Install ice machine on bin.NOTE: An optional caster assembly is available foruse in place of the legs. Installation instructions aresupplied with the casters.THREADLEVELING LEGINTO BASE OFCABINETTHREAD “FOOT”IN AS FAR ASPOSSIBLESV1606Leveling Leg and Foot