L NAPCO Security Systems X GEM-P1632 Programming Instructions!Page 43KEYPAD CONFIGURATION MODEThis section will focus on configuring the GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and GEM-RP4RFC/GEM-K4RF Keypads. If there is more than one keypad in the system, only Keypad No. 1 may be used forprogramming. For ease of programming, it is recommended that a GEM-RP1CAe2 or a GEM-K1CA be selected asKeypad #1 (see WI897 for Programming Instructions).KEYPAD INSTALLATIONEach keypad must be assigned an address number (1ñ7) and each requires its own configuration procedure (seeCONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1keypad must be used; only 1 is required for a single-area Commercial Burglary installation.GEM-RP2ASe2/GEM-K2AS - are utility LCD keypads combining several preset LCD words with a limitedmessage line. NOTE: Due to space constraints, available messages are abbreviated and will scrollautomatically.CONFIGURING THE KEYPADSKeypad Configuration Mode: Configuring the KeypadsConfiguring the GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and GEM-RP4RFC/GEM-K4RF KeypadsUp to 7 GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and/or GEM-RP4RFC/GEM-K4RF keypads maybe connected to the panel (Keypads 1ñ7). Each must be configured for a keypad address. In addition, the keypad maybe configured to disable (a) touchpad backlight; (b) LCD backlight; and (c) entry sounder. Keypads are configured bythe proper selection of jumpers. Refer to the label on the circuit board insulation paper for jumper locations and asummary of settings.KEYPAD ADDRESSIf more than one keypad is installed:! Each must be assigned a unique address (that is, no two keypadsmay be numbered alike).! Keypads must be addressed consecutively (that is, missingnumbers are not permitted).! Only Keypad No. 1 may be used for programming. (However, forease of programming, it is recommended that a GEM-RP1CAe2/GEM-K1CA be selected as Keypad #1).Assign the keypad address number by selecting Jumpers J1ñ3 inaccordance with the table at right.*Note: (1) Keypads are factory supplied with no jumpers installed and as such are automatically configured as KeypadNo. 1. (2) Only one keypad in the system may be configured as Keypad No. 1, otherwise none will function.TOUCHPAD BACK LIGHTCut Jumper A to disable touch pad backlighting to conserve 11mA standby current.LCD BACKLIGHTCut Jumper B to disable LCD backlighting.DISABLE SOUNDERCut Jumper C to disable the sounder. (Do not disable in UL applications.)KEYPADNUMBER 1 2 3 PARK1 OFF orON*OFF OFF2 OFF ON OFF STORE SPARE3 ON ON OFF JUMPER AT THIS4 OFF OFF OFF POSITION5 ON OFF ON6 OFF ON ON7 ON ON ONKEYPAD ADDRESS SETTING